Focal Pulsed Field Ablation of Ventricular Tachycardia
Ventricular Tachycardia (VT) · Structural Heart Disease · Ischemic Cardiomyopathy · Hypertrophic Cardiomyopathy (HCM) · Dilated Cardiomyopathy (DCM) · Arrhythmogenic Cardiomyopathy (AC, ARVD/C) · Electrical Storm
What this study involves
The registry does not currently label this study as recruiting. Ask about its status before planning a screening visit.
- Study type
- Observational
- Phase
- Not applicable / not listed
- Age range
- 18 years - Not specified
- Sex eligible
- All sexes
- Healthy volunteers
- Not accepted
- Participants
- 100 Estimated
These are starting points, not an eligibility decision. The research team must review the full requirements.
About the research
The PULSE-VT Registry is a combined retrospective and prospective, multi-centre, observational registry designed to evaluate the safety and efficacy of focal pulsed-field ablation (fPFA) using the Centauri™ generator for catheter ablation of ventricular tachycardia (VT). The registry captures detailed procedural, clinical, and follow-up data across participating electrophysiology centres performing VT ablation with this ablation energy modality.
Read the full description
The PULSE-VT Registry is a combined retrospective and prospective observational registry evaluating focal PFA for clinically indicated VT ablation using the Centauri™ PFA System. The Centauri system enables focal, point-by-point delivery of pulsed field energy and can be incorporated into established electroanatomical mapping workflows. This allows activation-guided, pace map-guided, and substrate-based VT ablation strategies to be performed using focal PFA in a manner analogous to conventional focal ablation workflows.
Patients enrolled in the registry will undergo VT ablation according to standard clinical practice and at the discretion of the treating electrophysiologist. Mapping strategies may include activation mapping, voltage mapping, substrate mapping, pace mapping, entrainment mapping, programmed ventricular stimulation, intracardiac imaging, coronary assessment, and integration of pre-procedural imaging when clinically indicated. Adjunctive radiofrequency ablation may be performed if considered clinically necessary and will be systematically documented.
The registry will collect data on patient characteristics, underlying heart disease, left ventricular function, arrhythmia indication, mapping strategy, procedural workflow, Centauri PFA application parameters, use of adjunctive ablation, acute procedural endpoints, and periprocedural complications. Safety outcomes of interest include pericardial effusion or tamponade, vascular complications, coronary spasm or coronary injury, conduction disturbances, ventricular arrhythmia induction, stroke, myocardial infarction, heart failure deterioration, and death.
Follow-up will be performed at approximately 3, 6, and 12 months and will assess VT recurrence, implantable cardioverter-defibrillator therapies, antitachycardia pacing, ICD shocks, arrhythmia-related hospitalization, repeat ablation, antiarrhythmic drug therapy, and survival.
The aim of the PULSE-VT Registry is to generate systematic real-world evidence on the feasibility, procedural characteristics, safety, acute efficacy, and short- to mid-term clinical outcomes of focal VT ablation using the Centauri PFA System.
Who may be able to participate?
The list below is the sponsor’s full registry wording. It can include conditions, prior treatment, test results and other requirements. A match in search does not mean you qualify.
Inclusion Criteria:
1. Age ≥ 18 years at the time of the ablation procedure
2. Documented ventricular tachycardia (sustained or non-sustained) requiring catheter ablation
3. Clinical indication for VT ablation including one or more of the following:
* Recurrent sustained VT
* Electrical storm (≥ 3 separate VT episodes within 24 hours)
* Recurrent ICD shock or anti-tachycardia pacing (ATP) therapy
* Recurrent non-sustained VT causing symptoms or haemodynamic compromise
4. Procedure performed using focal pulsed-field ablation (fPFA) with the Centauri™ generator (as primary or adjunctive ablation energy)
5. Written informed consent obtained
Exclusion Criteria:
1. Age \< 18 years
2. Refusal to provide consent for data collection
3. Ablation procedure performed without use of the Centauri™ PFA generator
4. Life expectancy \< 12 months due to non-cardiac comorbidity
5. Pregnancy at the time of the procedure
Study population
The study population consists of consecutive adult patients treated at participating centers who undergo clinically indicated catheter ablation for sustained ventricular tachycardia or recurrent ventricular arrhythmias using focal pulsed field ablation with the Centauri™ PFA System. Patients may have ischemic or non-ischemic structural heart disease, reduced or preserved left ventricular function, prior ICD therapies, electrical storm, recurrent VT, or drug-refractory ventricular arrhythmias. The decision to perform VT ablation and the procedural strategy are based solely on standard clinical care and the discretion of the treating electrophysiologist. Patients may be included retrospectively or prospectively if relevant procedural and follow-up data are available.
Understand screeningTreatment, groups and participation
The registry may describe treatments and study duration without a complete visit calendar. Ask the study team for the exact schedule, procedures, risks, costs and alternatives. Keep your usual care plan unless your treating clinician tells you otherwise.
- Assignment
- Not reported
- Masking
- Not reported
Patients with structural heart disease undergoing VT ablation with focal PFA
Patients included in the PULSE-VT Registry undergo clinically indicated catheter ablation of ventricular tachycardia using focal pulsed field ablation with the Centauri™ PFA System. The registry is observational and does not alter clinical decision-making, procedural strategy, or follow-up. Ablation is performed according to standard clinical practice and at the discretion of the treating electrophysiologist. The intervention of interest is focal, point-by-point PFA integrated into established electroanatomical mapping workflows. Mapping may include activation, substrate, pace, or entrainment mapping, programmed stimulation, intracardiac imaging, coronary assessment, and imaging integration when clinically indicated. Adjunctive radiofrequency ablation may be performed if clinically necessary and documented. Data on procedural characteristics, safety, acute efficacy, VT recurrence, ICD therapies, repeat ablation, hospitalization, antiarrhythmic drug use, and survival will be collected.
What researchers are measuring
Outcome measures describe what is being studied. They are not proof that a treatment works.
Primary measures
Freedom From Ventricular Tachycardia Recurrence After Focal PFA VT Ablation
Time frame: From index ablation with the Centauri™ PFA System procedure to 12 months of follow-up.
Proportion of patients free from recurrent ventricular tachycardia after clinically indicated VT ablation using the Centauri™ PFA System. VT recurrence is defined as documented sustained VT, appropriate ICD therapy including antitachycardia pacing or shock, arrhythmia-related hospitalization, or repeat VT ablation during follow-up.
Secondary measures
Incidence of Acute Procedure-Related Adverse Events
Time frame: Periprocedural
Proportion of patients experiencing acute procedure-related adverse events during or immediately after clinically indicated VT ablation using the Centauri™ PFA System. Events include pericardial effusion or tamponade, vascular complications, coronary spasm or coronary injury, conduction disturbances, stroke or transient ischemic attack, myocardial infarction, acute heart failure deterioration, sustained hemodynamic instability, procedure-related death, or other clinically relevant complications.
Acute Procedural Success of Focal PFA VT Ablation
Time frame: During the index ablation procedure; assessed at the end of the procedure.
Proportion of patients achieving acute procedural success after clinically indicated ventricular tachycardia ablation using the Centauri™ PFA System. Acute procedural success is defined as non-inducibility of the targeted clinical VT or relevant sustained monomorphic VT at the end of the procedure, and/or abolition of targeted arrhythmogenic substrate or local abnormal ventricular electrograms according to the predefined procedural strategy.
Review the complete result tables and limitations in the official record.
Open official results ↗Research locations (1)
The overall study status and a local site’s status can differ. Confirm that location’s availability before traveling.
1 locations
Sana HANSE Hospital WismarWismar, Mecklenburg-Vorpommern, GermanyStatus unknown
Study team and timeline
- Lead sponsor
- Sana Hanse Hospital Wismar
- Study start
- Jan 1, 2025 Actual
- Primary completion
- 2027-12 Estimated
- Study completion
- 2027-12 Estimated
- First posted
- Nov 10, 2026 Actual
- Last updated
- Nov 10, 2026 Actual
Official study contacts
No central contact is listed. Check the locations and the official record.
Official study title
Multicenter Study on Effectiveness and Safety of Focal Pulsed Field Ablation of Ventricular Tachycardia in Patients With Structural Heart Disease
Ask Wellness Clinical Research
Your message goes to WCR, including when this study is run by another organization. WCR may offer general guidance but may not operate this trial, have access to its team or be able to enroll you.
Source: ClinicalTrials.gov API v2. Information is submitted by sponsors and investigators. NLM does not approve the safety or science of all listed studies. Registry disclaimer.
Retrieved: Nov 12, 2026 · Last registry update: Nov 10, 2026