MicroVention, Inc. Flow Re-Direction Endoluminal Device X (FRED™ X™) Post-Approval Study
Intracranial Aneurysm
De qué trata este estudio
El registro no identifica actualmente este estudio como reclutando. Consulta su estado antes de planificar una evaluación.
- Tipo de estudio
- De intervención
- Fase
- No aplica
- Rango de edad
- 22 años - 75 años
- Sexo admitido
- Todos los sexos
- Voluntarios sanos
- No aceptados
- Participantes
- 154 Estimado
Estos son puntos de partida, no una decisión de elegibilidad. El equipo debe revisar todos los requisitos.
Las explicaciones y la navegación están en español. Los textos proporcionados por el registro, incluidos títulos, resúmenes y criterios, se conservan en su idioma original. Puedes pedir orientación en español a WCR.
Acerca de la investigación
The objective of this study is to generate contemporaneous clinical data to facilitate a reasonable comparison of the performance of the FRED™ X™ device with the performance of the FRED™ device. The data generated from this study will be compared to the safety and effectiveness of the FRED™ device by meeting the same performance goals (PGs) established for the FRED™ pivotal study.
¿Quién podría participar?
La lista siguiente contiene el texto del patrocinador. Puede incluir condiciones, tratamientos previos, resultados de pruebas y otros requisitos. Aparecer en tu búsqueda no significa que califiques.
Inclusion Criteria:
Subjects for this study must meet ALL the following criteria:
1. Subject has single target aneurysm in the internal carotid artery from petrous segment to the terminus of the internal carotid artery.
2. The parent artery diameter must be 2.0 - 5.0 mm distal and/or proximal to the target intracranial aneurysm.
3. Negative pregnancy test (serum or urine) in a female subject who has had menses in the last 18 months.
4. Subject commits to return to the investigational site for the 30- day, 6-month, 12-month, 2-year, 3-year, and 5-year follow-up evaluations.
5. The subject or his/her authorized representative must sign the IRB-approved written informed consent form prior to the start of any study procedures.
6. The subject has a modified Rankin Scale (mRS) ≤ 2.
7. The subject has a wide-necked ( ≥4mm or dome-to-neck ratio \<2) saccular or fusiform aneurysm.
Exclusion Criteria:
Subjects shall be excluded from the study if ANY of the following conditions exist:
1. Subject who suffers from a subarachnoid hemorrhage in the last 60 days.
2. Subject who suffers from intracranial hemorrhage in the last 30 days.
3. Subject who presents with an intracranial mass or currently undergoing radiation therapy for carcinoma of the head or neck region.
4. Subject with symptomatic extracranial or intracranial stenosis of the parent artery (\>50%) proximal to the target aneurysm.
5. Subject with an irreversible bleeding disorder, a platelet count \< 100 x 103 cells/mm3 or known platelet dysfunction or a contraindication to or inability to tolerate anticoagulants/antiplatelet agents or thrombolytic drugs.
6. Subject with history of major bleeding disorder (based on coagulation profile and platelet count) and/or subject presents with signs of active bleeding.
7. Subject with known hypersensitivity to any component of the treatment device that cannot be medically controlled.
8. Subject with documented contrast allergy, or other condition that prohibits imaging.
9. Evidence of active bacterial infection at the time of treatment.
10. Presence of any of the following unequivocal cardiac sources of embolism: chronic or paroxysmal atrial fibrillation, mitral stenosis, mechanical valve, endocarditis, intracardiac clot or vegetation, myocardial infarction within 3 months, dilated cardiomyopathy, left atrial spontaneous echo contrast, ejection fraction less than 30%.
11. Subject with a pre-existing stent in place at the target aneurysm.
12. Subject who is unable to complete the required follow-ups.
13. Subject who is pregnant, breastfeeding, or of childbearing potential and unwilling to prevent pregnancy during their participation in the study.
14. Subject has a serious or life-threatening comorbidity that could confound study results and/or prevent completion of 5-year followup.
15. Subject is enrolled in another device or drug study in which participation could confound study results.
16. Subject has absent femoral pulses or other condition preventing femoral access, or is planned to be treated using a radial access approach.
Tratamiento, grupos y participación
El registro puede describir tratamientos y duración sin incluir un calendario completo. Pide al equipo las visitas, procedimientos, riesgos, costos y alternativas. Mantén tu atención habitual salvo que tu médico te indique un cambio.
- Asignación
- No aplica
- Enmascaramiento
- Sin enmascaramiento
Flow Re-Direction Endoluminal Device X
FRED™ X™ device
Device: FRED™ X™
FRED™ X™ DEVICE
The FRED™ X™ System is indicated for use in the internal carotid artery from the petrous segment to the terminus for the endovascular treatment.
Qué evalúan los investigadores
Estas medidas indican qué se estudia. No prueban que un tratamiento funcione.
Medidas principales
Primary Safety Endpoint Part 1: Proportion of subjects that experience either Death or major stroke within 30 days post-procedure.
Plazo: 30-days
Major stroke is defined as a new neurological event that persists for \>24 hours and results in a ≥4-point increase in the NIHSS score compared to baseline or compared to any subsequent lower score.
Primary Safety Endpoint Part 2: Proportion of subjects that experience neurological death or major ipsilateral stroke within 12 months post-procedure.
Plazo: 12 months
A major ipsilateral stroke is defined as that occurring within the vascular distribution of the stented artery. Neurological death is defined as a death which has been adjudicated by an independent clinical events committee to have directly resulted from a neurologic cause.
Primary Effectiveness Endpoint: The percent of subjects with (1) complete (100%) occlusion of the target aneurysm and ≤50% stenosis of the parent artery at the target IA, and (2) in whom an alternative treatment of the target IA had not been performed.
Plazo: 12 months
(1) Complete (100%) occlusion of the target aneurysm is assessed utilizing the Raymond-Roy Scale (Raymond Roy Class 1) and ≤50% stenosis of the parent artery at the target IA), and in whom an alternative treatment of the target IA had not been performed. The study will utilize independent Core Laboratory to adjudicate all angiographic outcomes, including aneurysm occlusion status and parent artery stenosis. (2) Alternative treatment is defined as re-treatment of the target aneurysm with an alternative treatment modality including open repair, endovascular placement of an additional stent or treatment of in-stent stenosis.
Revisa las tablas completas y sus limitaciones en el registro oficial.
Abrir resultados oficiales ↗Centros de investigación (23)
El estado general puede diferir del estado de un centro. Confirma la disponibilidad antes de trasladarte.
23 centros
Memorial Healthcare SystemsHollywood, Florida, United StatesEstado desconocido
Orlando HealthOrlando, Florida, United StatesEstado desconocido
Queen's Medical CenterHonolulu, Hawaii, United StatesEstado desconocido
University of IowaIowa City, Iowa, United StatesEstado desconocido
University of KansasKansas City, Kansas, United StatesEstado desconocido
Baptist Healthcare SystemLouisville, Kentucky, United StatesEstado desconocido
Norton HealthcareLouisville, Kentucky, United StatesEstado desconocido
Ochsner HealthNew Orleans, Louisiana, United StatesEstado desconocido
The Johns Hopkins UniversityBaltimore, Maryland, United StatesEstado desconocido
Massachusetts General Brigham IncorporatedBoston, Massachusetts, United StatesEstado desconocido
UMass Memorial HealthWorcester, Massachusetts, United StatesEstado desconocido
Albany Medical CenterAlbany, New York, United StatesEstado desconocido
University at BuffaloBuffalo, New York, United StatesEstado desconocido
Northwell HealthManhasset, New York, United StatesEstado desconocido
Mount SinaiNew York, New York, United StatesEstado desconocido
Stony Brook UniversityStony Brook, New York, United StatesEstado desconocido
Montefiore Medical CenterThe Bronx, New York, United StatesEstado desconocido
Ohio State UniversityColumbus, Ohio, United StatesEstado desconocido
ProMedica Toledo HospitalToledo, Ohio, United StatesEstado desconocido
University of Oklahoma Health Sciences CenterOklahoma City, Oklahoma, United StatesEstado desconocido
University of PennsylvaniaPhiladelphia, Pennsylvania, United StatesEstado desconocido
Thomas Jefferson UniversityPhiladelphia, Pennsylvania, United StatesEstado desconocido
Houston Methodist HospitalHouston, Texas, United StatesEstado desconocido
Equipo y fechas
- Patrocinador principal
- Microvention-Terumo, Inc.
- Inicio del estudio
- 20 sept 2022 Real
- Finalización primaria
- 2027-04 Estimado
- Finalización del estudio
- 2030-05 Estimado
- Primera publicación
- 8 jun 2022 Real
- Última actualización
- 10 nov 2026 Real
Contactos oficiales del estudio
No hay un contacto central indicado. Revisa los centros y el registro oficial.
Título oficial del estudio
MicroVention, Inc. Flow Re-Direction Endoluminal Device X (FRED™ X™) Post-Approval Study
Consulta a Wellness Clinical Research
Tu mensaje va a WCR, incluso si otra organización realiza este estudio. WCR puede orientarte, pero podría no realizar este estudio, tener acceso a su equipo ni poder inscribirte.
Fuente: API v2 de ClinicalTrials.gov. Patrocinadores e investigadores envían la información. La NLM no aprueba la seguridad ni la ciencia de todos los estudios registrados. Aviso del registro.
Consultado: 12 nov 2026 · Última actualización del registro: 10 nov 2026